[BACK]Return to portal_vfsops.c CVS log [TXT][DIR] Up to [local] / sys / miscfs / portal

Annotation of sys/miscfs/portal/portal_vfsops.c, Revision 1.1.1.1

1.1       nbrk        1: /*     $OpenBSD: portal_vfsops.c,v 1.21 2007/06/18 08:30:07 jasper Exp $       */
                      2: /*     $NetBSD: portal_vfsops.c,v 1.14 1996/02/09 22:40:41 christos Exp $      */
                      3:
                      4: /*
                      5:  * Copyright (c) 1992, 1993
                      6:  *     The Regents of the University of California.  All rights reserved.
                      7:  *
                      8:  * This code is derived from software donated to Berkeley by
                      9:  * Jan-Simon Pendry.
                     10:  *
                     11:  * Redistribution and use in source and binary forms, with or without
                     12:  * modification, are permitted provided that the following conditions
                     13:  * are met:
                     14:  * 1. Redistributions of source code must retain the above copyright
                     15:  *    notice, this list of conditions and the following disclaimer.
                     16:  * 2. Redistributions in binary form must reproduce the above copyright
                     17:  *    notice, this list of conditions and the following disclaimer in the
                     18:  *    documentation and/or other materials provided with the distribution.
                     19:  * 3. Neither the name of the University nor the names of its contributors
                     20:  *    may be used to endorse or promote products derived from this software
                     21:  *    without specific prior written permission.
                     22:  *
                     23:  * THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
                     24:  * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
                     25:  * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
                     26:  * ARE DISCLAIMED.  IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
                     27:  * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
                     28:  * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
                     29:  * OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
                     30:  * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
                     31:  * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
                     32:  * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
                     33:  * SUCH DAMAGE.
                     34:  *
                     35:  *     from: Id: portal_vfsops.c,v 1.5 1992/05/30 10:25:27 jsp Exp
                     36:  *     @(#)portal_vfsops.c     8.6 (Berkeley) 1/21/94
                     37:  */
                     38:
                     39: /*
                     40:  * Portal Filesystem
                     41:  */
                     42:
                     43: #include <sys/param.h>
                     44: #include <sys/systm.h>
                     45: #include <sys/time.h>
                     46: #include <sys/types.h>
                     47: #include <sys/proc.h>
                     48: #include <sys/filedesc.h>
                     49: #include <sys/file.h>
                     50: #include <sys/vnode.h>
                     51: #include <sys/mount.h>
                     52: #include <sys/namei.h>
                     53: #include <sys/malloc.h>
                     54: #include <sys/mbuf.h>
                     55: #include <sys/socket.h>
                     56: #include <sys/socketvar.h>
                     57: #include <sys/protosw.h>
                     58: #include <sys/domain.h>
                     59: #include <sys/un.h>
                     60: #include <miscfs/portal/portal.h>
                     61:
                     62: #define portal_init ((int (*)(struct vfsconf *))nullop)
                     63:
                     64: int    portal_mount(struct mount *, const char *, void *,
                     65:                          struct nameidata *, struct proc *);
                     66: int    portal_start(struct mount *, int, struct proc *);
                     67: int    portal_unmount(struct mount *, int, struct proc *);
                     68: int    portal_root(struct mount *, struct vnode **);
                     69: int    portal_statfs(struct mount *, struct statfs *, struct proc *);
                     70:
                     71:
                     72: /*
                     73:  * Mount the per-process file descriptors (/dev/fd)
                     74:  */
                     75: int
                     76: portal_mount(struct mount *mp, const char *path, void *data, struct nameidata *ndp,
                     77:     struct proc *p)
                     78: {
                     79:        struct file *fp;
                     80:        struct portal_args args;
                     81:        struct portalmount *fmp;
                     82:        struct socket *so;
                     83:        struct vnode *rvp;
                     84:        size_t size;
                     85:        int error;
                     86:
                     87:        /*
                     88:         * Update is a no-op
                     89:         */
                     90:        if (mp->mnt_flag & MNT_UPDATE)
                     91:                return (EOPNOTSUPP);
                     92:
                     93:        error = copyin(data, &args, sizeof(struct portal_args));
                     94:        if (error)
                     95:                return (error);
                     96:
                     97:        if ((error = getsock(p->p_fd, args.pa_socket, &fp)) != 0)
                     98:                return (error);
                     99:        so = (struct socket *) fp->f_data;
                    100:        if (so->so_proto->pr_domain->dom_family != AF_UNIX) {
                    101:                FRELE(fp);
                    102:                return (ESOCKTNOSUPPORT);
                    103:        }
                    104:
                    105:        error = getnewvnode(VT_PORTAL, mp, portal_vnodeop_p, &rvp); /* XXX */
                    106:        if (error) {
                    107:                FRELE(fp);
                    108:                return (error);
                    109:        }
                    110:        MALLOC(rvp->v_data, void *, sizeof(struct portalnode),
                    111:                M_TEMP, M_WAITOK);
                    112:
                    113:        fmp = (struct portalmount *) malloc(sizeof(struct portalmount),
                    114:                                 M_MISCFSMNT, M_WAITOK);
                    115:        rvp->v_type = VDIR;
                    116:        rvp->v_flag |= VROOT;
                    117:        VTOPORTAL(rvp)->pt_arg = 0;
                    118:        VTOPORTAL(rvp)->pt_size = 0;
                    119:        VTOPORTAL(rvp)->pt_fileid = PORTAL_ROOTFILEID;
                    120:        fmp->pm_root = rvp;
                    121:        fmp->pm_server = fp;
                    122:        fp->f_count++;
                    123:        FRELE(fp);
                    124:
                    125:        mp->mnt_flag |= MNT_LOCAL;
                    126:        mp->mnt_data = fmp;
                    127:        vfs_getnewfsid(mp);
                    128:
                    129:        (void) copyinstr(path, mp->mnt_stat.f_mntonname, MNAMELEN - 1, &size);
                    130:        bzero(mp->mnt_stat.f_mntonname + size, MNAMELEN - size);
                    131:        (void) copyinstr(args.pa_config, mp->mnt_stat.f_mntfromname,
                    132:            MNAMELEN - 1, &size);
                    133:        bzero(mp->mnt_stat.f_mntfromname + size, MNAMELEN - size);
                    134:        return (0);
                    135: }
                    136:
                    137: int
                    138: portal_start(struct mount *mp, int flags, struct proc *p)
                    139: {
                    140:
                    141:        return (0);
                    142: }
                    143:
                    144: int
                    145: portal_unmount(struct mount *mp, int mntflags, struct proc *p)
                    146: {
                    147:        struct vnode *rvp = VFSTOPORTAL(mp)->pm_root;
                    148:        int error, flags = 0;
                    149:
                    150:        if (mntflags & MNT_FORCE) {
                    151:                flags |= FORCECLOSE;
                    152:        }
                    153:
                    154:        /*
                    155:         * Clear out buffer cache.  I don't think we
                    156:         * ever get anything cached at this level at the
                    157:         * moment, but who knows...
                    158:         */
                    159: #ifdef notyet
                    160:        mntflushbuf(mp, 0);
                    161:        if (mntinvalbuf(mp, 1))
                    162:                return (EBUSY);
                    163: #endif
                    164:        if (rvp->v_usecount > 1 && !(flags & FORCECLOSE))
                    165:                return (EBUSY);
                    166:        if ((error = vflush(mp, rvp, flags)) != 0)
                    167:                return (error);
                    168:
                    169:        /*
                    170:         * Release reference on underlying root vnode
                    171:         */
                    172:        vrele(rvp);
                    173:        /*
                    174:         * And blow it away for future re-use
                    175:         */
                    176:        vgone(rvp);
                    177:        /*
                    178:         * Shutdown the socket.  This will cause the select in the
                    179:         * daemon to wake up, and then the accept will get ECONNABORTED
                    180:         * which it interprets as a request to go and bury itself.
                    181:         */
                    182:        FREF(VFSTOPORTAL(mp)->pm_server);
                    183:        soshutdown((struct socket *) VFSTOPORTAL(mp)->pm_server->f_data, 2);
                    184:        /*
                    185:         * Discard reference to underlying file.  Must call closef because
                    186:         * this may be the last reference.
                    187:         */
                    188:        closef(VFSTOPORTAL(mp)->pm_server, NULL);
                    189:        /*
                    190:         * Finally, throw away the portalmount structure
                    191:         */
                    192:        free(mp->mnt_data, M_MISCFSMNT);
                    193:        mp->mnt_data = 0;
                    194:        return (0);
                    195: }
                    196:
                    197: int
                    198: portal_root(struct mount *mp, struct vnode **vpp)
                    199: {
                    200:        struct vnode *vp;
                    201:        struct proc *p = curproc;
                    202:
                    203:        /*
                    204:         * Return locked reference to root.
                    205:         */
                    206:        vp = VFSTOPORTAL(mp)->pm_root;
                    207:        VREF(vp);
                    208:        vn_lock(vp, LK_EXCLUSIVE | LK_RETRY, p);
                    209:        *vpp = vp;
                    210:        return (0);
                    211: }
                    212:
                    213: int
                    214: portal_statfs(struct mount *mp, struct statfs *sbp, struct proc *p)
                    215: {
                    216:
                    217:        sbp->f_bsize = DEV_BSIZE;
                    218:        sbp->f_iosize = DEV_BSIZE;
                    219:        sbp->f_blocks = 2;              /* 1K to keep df happy */
                    220:        sbp->f_bfree = 0;
                    221:        sbp->f_bavail = 0;
                    222:        sbp->f_files = 1;               /* Allow for "." */
                    223:        sbp->f_ffree = 0;               /* See comments above */
                    224:        if (sbp != &mp->mnt_stat) {
                    225:                bcopy(&mp->mnt_stat.f_fsid, &sbp->f_fsid, sizeof(sbp->f_fsid));
                    226:                bcopy(mp->mnt_stat.f_mntonname, sbp->f_mntonname, MNAMELEN);
                    227:                bcopy(mp->mnt_stat.f_mntfromname, sbp->f_mntfromname, MNAMELEN);
                    228:        }
                    229:        strncpy(sbp->f_fstypename, mp->mnt_vfc->vfc_name, MFSNAMELEN);
                    230:        return (0);
                    231: }
                    232:
                    233:
                    234: #define portal_sync ((int (*)(struct mount *, int, struct ucred *, \
                    235:                                  struct proc *))nullop)
                    236:
                    237: #define portal_fhtovp ((int (*)(struct mount *, struct fid *, \
                    238:            struct vnode **))eopnotsupp)
                    239: #define portal_quotactl ((int (*)(struct mount *, int, uid_t, caddr_t, \
                    240:            struct proc *))eopnotsupp)
                    241: #define portal_sysctl ((int (*)(int *, u_int, void *, size_t *, void *, \
                    242:            size_t, struct proc *))eopnotsupp)
                    243: #define portal_vget ((int (*)(struct mount *, ino_t, struct vnode **)) \
                    244:            eopnotsupp)
                    245: #define portal_vptofh ((int (*)(struct vnode *, struct fid *))eopnotsupp)
                    246: #define portal_checkexp ((int (*)(struct mount *, struct mbuf *,       \
                    247:        int *, struct ucred **))eopnotsupp)
                    248:
                    249: const struct vfsops portal_vfsops = {
                    250:        portal_mount,
                    251:        portal_start,
                    252:        portal_unmount,
                    253:        portal_root,
                    254:        portal_quotactl,
                    255:        portal_statfs,
                    256:        portal_sync,
                    257:        portal_vget,
                    258:        portal_fhtovp,
                    259:        portal_vptofh,
                    260:        portal_init,
                    261:        portal_sysctl,
                    262:        portal_checkexp
                    263: };

CVSweb