[BACK]Return to M188 CVS log [TXT][DIR] Up to [local] / sys / arch / mvme88k / conf

Annotation of sys/arch/mvme88k/conf/M188, Revision 1.1.1.1

1.1       nbrk        1: #      $OpenBSD: M188,v 1.28 2006/05/28 11:09:56 miod Exp $
                      2:
                      3: machine mvme88k m88k
                      4:
                      5: include "../../../conf/GENERIC"
                      6:
                      7: # Processor type
                      8: option         M88100
                      9: option         M88110
                     10:
                     11: option         MVME188         # support for 188 (requires M88100)
                     12:
                     13: # Define this if your processor has the xxx.usr bug (mask C82N)
                     14: option         ERRATA__XXX_USR
                     15:
                     16: maxusers 64
                     17:
                     18: config bsd swap on generic
                     19:
                     20: # ------------------------------ devices --------------------------------
                     21: mainbus0 at root
                     22:
                     23: # ------------------------------ mainbus devices ------------------------
                     24: syscon0 at mainbus0 addr 0xfff00000
                     25:
                     26: # ------------------------------ syscon0 devices ------------------------
                     27: nvram0 at syscon0 offset 0x80000
                     28: dart0  at syscon0 offset 0x82000 ipl 3
                     29: vme0   at syscon0 offset 0x85000
                     30:
                     31: # ------------------------------ vme0 devices --------------------------
                     32: vmes0  at vme0
                     33: vmel0  at vme0
                     34:
                     35: # ------------------------------ vmes0 devices -------------------------
                     36: vx0    at vmes0 addr 0xff780000 ipl 3
                     37: vx1    at vmes0 addr 0xff790000 ipl 3
                     38: vx2    at vmes0 addr 0xff7a0000 ipl 3
                     39: vx3    at vmes0 addr 0xff7b0000 ipl 3
                     40: le0    at vmes0 addr 0xffff1200 ipl 3
                     41: le1    at vmes0 addr 0xffff1400 ipl 3
                     42: le2    at vmes0 addr 0xffff1600 ipl 3
                     43: vs0    at vmes0 addr 0xffff9000 ipl 2
                     44: vs1    at vmes0 addr 0xffff9800 ipl 2
                     45: vs2    at vmes0 addr 0xffff4800 ipl 2
                     46: vs3    at vmes0 addr 0xffff5800 ipl 2
                     47: vs4    at vmes0 addr 0xffff7000 ipl 2
                     48: vs5    at vmes0 addr 0xffff7800 ipl 2
                     49:
                     50: # ------------------------------- vs0 devices --------------------------
                     51: scsibus* at vs?
                     52:
                     53: # ------------------------------ scsibus devices -----------------------
                     54: sd*    at scsibus?
                     55: st*    at scsibus?
                     56: cd*    at scsibus?

CVSweb